This guide shows the step-by-step process on how to use the example Codesys project and make it communicate with the Realtime controller to control the robots in the Getting Started Guide example project.

Table of Contents

1 Prerequisites

Install Codesys on a Windows System

  1. Install Codesys V3.5 SP14 x64 or newer on a Windows System

    1. Download the Codesys installer from https://store.codesys.com/codesys.html.

A Codesys account is necessary to proceed with download, so when a user is not logged in, pressing Download will prompt a dialog box leading the user to the “Login or Create an Account” page

Once logged in as a user, the user would have the option to download the 32-bit or 64-bit installer.

2 Setup and Execution

2.1 Realtime Controller

  1. Create a group and load the projects in the Control Panel

The Getting Started Example Project is loaded for this example with the group named as ‘Test’. You can download the project files for the Control Panel below.

View file
nameTraining Guide_RapidPlan 1.2.1 - Control Panel Projects.zip

Image RemovedImage Added

2.2 Codesys

The Codesys library files and example Codesys projects are available in the RealtimeExamples [WIP 1.3.0] Examples github repository. The files are located inside the PLC/RealtimeCodesysControl/ folder. The folder structure of the repository is as follows.

Code Block
RealtimeExamples
├── PLC/RealtimeCodesysControl
│   ├── ExampleProject
│   ├── LibraryCode
│   ├── MELCOPickExample
├── C#
└── python

Open Codesys (Codesys v3.5 SP16 is used in this guide)

  1. Install the RTR Controller Library.compiled-library file into codesys

    1. From the menu bar: Tools -> Library Respository -> Install

Image RemovedImage RemovedImage AddedImage Added

b. Choose the RTR Controller Library.compiled-library file.

This file is located in the LibraryCode folder.

Image RemovedImage Added

The library should show up in the installed libraries list when the library is successfully installed

Image RemovedImage Added
    3.
    1. Launch the Example Project (ExampleProject.project)

    This file is located in the ExampleProject folder.

    Image RemovedImage Added

    The project should be loaded as shown in the image below

    Image RemovedImage Added

    4. Configure the necessary parameters in RunRobotA and RunRobotB

    Image RemovedImage Added
    • Configure the following parameters for RunRobotA and RunRobotB in the program and the logic diagram

    Program

    ParameterName

    Value

    RunRobotA / RunRobotB

    ProjectName

    RTR_Example_Project_Left_Bot / RTR_Example_Project_Right_Bot

    RunRobotA & RunRobotB

    RTC_IP

    Realtime Controller IP address

    (e.g. 192.168.0.10)

    RunRobotA & RunRobotB

    GroupName

    Deconfliction group name

    (e.g. ‘Test’)

    RunRobotA & RunRobotB

    HubOrder

    ['staging', ‘place_1_1’, ‘place_1_2’, ‘place_1_3’, ‘place_1_4’, ‘place_2_1’, ‘place_2_1’]

    RunRobotA & RunRobotB

    Work_State_Name (Logic Diagram)

    ‘no_part'

    Check the IP address of the workstation or system running the Realtime Controller appliance using ifconfig in a terminal. 5.

    1. Make sure that all the libraries are installed into the system by double clicking on the Library Manager

    Unavailable libraries will have a warning mark in their icon and show a message that the library is unavailable when the mouse is hovered over it as shown in the image below

    Image RemovedImage Added
      6.
      1. Make sure that RunRobotA and RunRobotB are added to the main task.

      The ExampleProject has RunRobotB_1 called in the MainTask. This step can be skipped if the ExampleProject you’re working on already has RunRobotA and RunRobotB under MainTask.

      The following video shows how to remove the RunRobotB_1 call and how to add RunRobotA and RunRobotB call to the MainTask.

      set_main_task_calls.mp4

      a. Double-click on MainTask (IEC-Tasks) on the Devices pane.

      b. Click on RunRobotB_1 and click on Remove Call.

      c. Click Add Call and choose RunRobotA or RunRobotB under Applications > Two Robots Moving To Hubs. Do this for both RunRobotA and RunRobotB.

      7.
      1. Start the Codesys Control Win v3x64 soft PLC

      a. Click on the Show hidden icons button in the task bar

      Image RemovedImage Added

      b. Right click on the Codesys Control Systray icon (the icon of a gray box with 64 in black) and select StartPLC. The 64 on the icon will turn red once the PLC is started.

      Image RemovedImage Added
        8.
        1. Scan Network and select the soft PLC

        a. Double click on the Device icon in the Devices panel

        Image RemovedImage Added

        b. Click on Scan Network and select the device

        Image RemovedImage Added
          9.
          1. Download project to the soft PLC then run the program

          The project can be built by clicking on the Build icon on the toolbar or by pressing F11. Make sure that there are no errors by checking the log message in the status bar.

          When logging in for the first time with the active application, you will be prompted whether the application “Sim.<device name>.<application name>” should be created and loaded. Click Yes to confirm.

          Image RemovedImage Added

          Pressing the Login button allows you to connect the application to the target system (PLC to simulated device) and allows you to go to online mode which allows you to run the application using the play icon.

          Image RemovedImage Added

          10. Toggle InitEnable then EnableOpMode in both RunRobotA and RunRobotB

          codesys_start_task.mp4

          11. Toggle Run bit in both RunRobotA and RunRobotB. This allows the robot to move by cycling to the hubs in the HubList. Toggling the Run bit off will stop the PLC from sending commands. Toggling the Reset bit at the bottom of the logic diagram would reset the application and move the robots to the ‘home’ hub.

          codesys_run_task.mp4

          3 How To

          3.1 Add a new Ladder Logic Diagram Program POU

          This section shows a step-by-step procedure on how to add a new ladder logic diagram program POU

          1. Right click on the Devices pane on the right side of the screen and select Add Object → POU

          2. In the Add POU dialog box, select Program as the POU Type

          3. Make sure that the Implementation Language that is selected is Ladder Logic Diagram (LD)

          4. Edit the name of the POU and click Add.

          new_program.mp4

          3.2 Add RTR library blocks in the ladder diagram

          The example uses a Program POU with Ladder Logic Diagram (LD) as implementation language. A Program POU with Ladder Logic Diagram consists of the upper and lower pane. The upper pane is where the variables can be defined and can be set to be either in textular or tabular view. The lower pane is where the ladder diagram can be constructed and RTR library blocks can be added.

          The user can add the RTR library blocks in the ladder diagram by doing the following:

          1. Right click on the Logic Diagram side of the program and select Empty box with EN/EN0

          2. Click on the block title

          3. Click on the button with ellipsis (…) beside the block title and select the RTR library block you want to add (We will be using TCP_Connect in this example) and click OK. The parameters of the empty box will be updated once you click somewhere outside the box.

          4. Click on each of the input and output parameters and enter the necessary information (variables are defined on the upper pane of the program)

          The video attached shows how TCP_Connect is added in the ladder diagram.

          add_manually.mp4

          4 Devices supported by Codesys

          To use actual PLCs, downloaded the PLC program to the actual PLC instead of downloading it to the Codesys SoftPLC as shown in this guide.

          The list of PLCs supported by Codesys can be accessed here. Schneider Electric, Beckhoff, WAGO, and Festo among others use Codesys as their standard programming interface.

          5 Codesys Realtime Controller Function Blocks

          5.1 PLC Program Variables

          5.1.1 ConfigurationStrings

          Variable Name

          Type

          Description

          Project Name

          STRING

          Project Name for each robot

          RTC_IP

          STRING

          IP address of the Realtime Controller

          GroupName

          STRING

          Group Name for Init Group

          HubOrder

          ARRAY[0..n] OF STRING

          Array of Hubs

          5.1.2 HMI Buttons

          Variable Name

          Type

          Description

          Configure

          BOOL

          Enter Configuration Mode

          RUN

          BOOL

          Moves from config to run mode and runs the robots

          xRESET

          BOOL

          Resets everything and moves robots back to home

          Priority

          BOOL

          If TRUE, robot will not go to staging but will wait in place. If FALSE, robot will go to staging.

          5.1.3 Realtime Controller Library Block Enable Bits

          Variable Name

          Type

          Description

          Connect

          BOOL

          Connect to robot

          InitEnable

          BOOL

          send INIT command to RTR controller

          EnableOpMode

          BOOL

          Bit to trigger the BeginOperationMode Command

          OffroadToHome

          BOOL

          Bit to enable the offroadmap move back to home

          5.1.4 Realtime Controller Library Blocks

          Variable Name

          Realtime Controller Library Block

          TCP_Connect

          TCP_Connect

          hc_A

          RTR.CAA.HANDLE

          InitGroup

          InitGroup

          MoveToHub

          MoveToHub

          MoveToStage

          MoveToHub

          MoveToHome

          MoveToHub

          BeginOperationMode

          BeginOperationMode

          OffroadToHub

          OffroadToHub

          5.2 Realtime Controller Library Block Specifications

          The following diagrams show the different Realtime Controller library blocks used in the PLC example program with their corresponding input and output parameters.

          5.2.1 TCP_Connect

          Image RemovedImage Added

          Input Parameters

          Parameter Name

          Description

          xConnect

          Connects on rising edge; connection remains open while true

          xReset

          Reset connection

          strConfigIPAddress

          IP address of appliance as a string (e.g. 192.168.0.4)

          uiConfigPort

          Port to connect to on the appliance (e.g. 9999)

          Output Parameters

          Parameter Name

          Description

          hConnection

          Required socket info for all appliance blocks

          strDiagnose

          Status of the block

          xReady

          TRUE when connected

          5.2.2 InitGroup

          Input Parameters

          Parameter Name

          Description

          Enable

          Message sent on rising edge | Disable to reset block

          Deconfliction_Group

          String value for deconfliction group

          Project_Name

          String value for project name

          Work_State_Name

          String value for roadmap workstate

          hConnection

          Required socket info for all appliance blocks

          Output Parameters

          Parameter Name

          Description

          Done

          True when valid response is received

          Output

          String output of the response

          Result

          Output of the error code from the RTR controller

          Status

          Current status of this block

          Error

          True when a non-zero value is returned from the appliance

          5.2.3 BeginOperationMode

          Image RemovedImage Added

          Input Parameters

          Parameter Name

          Description

          Enable

          Message sent on rising edge | Disable to reset block

          hConnection

          Required socket info for all appliance blocks

          Output Parameters

          Parameter Name

          Description

          Done

          True when valid response is received

          Output

          String output of the response

          Result

          Output of the error code from the RTR controller

          Status

          Current status of this block

          Error

          True when a non-zero value is returned from the appliance

          5.2.4 MoveToHub

          Image RemovedImage Added

          Input Parameters

          Parameter Name

          Description

          Enable

          Message sent on rising edge | Disable to reset block

          Project_Name

          String value for project name

          Work_State_Name

          String value for roadmap workstate

          HubName

          String value for hub name

          Speed

          String value for robot speed (1 = full speed, 0.1 = 10% speed)

          hConnection

          Required socket info for all appliance blocks

          Output Parameters

          Parameter Name

          Description

          Done

          True when valid response is received

          Output

          String output of the response

          Result

          Output of the error code from the RTR controller

          Status

          Current status of this block

          Error

          True when a non-zero value is returned from the appliance

          5.2.5 OffroadToHub

          Image RemovedImage Added

          Input Parameters

          Parameter Name

          Description

          Enable

          Message sent on rising edge | Disable to reset block

          Project_Name

          String value for project name

          Work_State_Name

          String value for roadmap workstate

          HubName

          String value for hub name

          Path_Quality

          String value for the desired quality of the executed path (“low”, “medium”, “high”)

          Timeout

          String value for the amount of time given to plan the path to the hub, in seconds.

          hConnection

          Required socket info for all appliance blocks

          Output Parameters

          Parameter Name

          Description

          Done

          True when valid response is received

          Output

          String output of the response

          Result

          Output of the error code from the RTR controller

          Status

          Current status of this block

          Error

          True when a non-zero value is returned from the appliance