During the calibration process, the static Aruco tag in the scene is found and the image is cached to compare against during system running in order to detect when the sensors may have been shifted out of calibration. When it is detected that a sensor may have been shifted out of calibration, GetRapidSenseStatus is set to false for Is_calibrated for that particular sensor in order to warn the user that the calibration needs to be adjusted and run again.
Check the configuration
After the calibration check of the system is properly configured, use ScanScene command to show obstacles detected by RapidSense. Verify that the detected obstacles match the actual cells. Incorrect orientation of the calibration tag may result in the following.
...
Sample cal.json File for (2) Sensors
...