Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

We are thrilled to announce the new release! This update brings a host of new features, improvements, and bug fixes designed to enhance your user experience and improve overall performance.

...

✅ A cleaner and more intuitive layout

...

  • Fanuc Robot always changes Robot Speed to 100 when acquiring control (ID:27440)

  • Profinet Lookup Table breaking updates:

    • Group targets by robot/preset and frames by World/parent robot (ID:35201)

    • Data is sorted alphabetically (exceptions: stateful objects come first, Origin frame always has id 0) (ID:37577)

...

3. RapidPlan ASCII API

...

...

3.1. Major Improvements

  • Added validation argument to UpdateTarget command

  • Added BlockMove + ContinueMove commands (more details to come), also updated CombinedMove with new optional blockMove argument

  • Updated Move command with a new argument constraint.

  • Correction of the preset-switching behavior in a CombinedMove command.

  • Updated name of HoldMove and ResumeMove commands (prev. block/continue)

  • Added MultiRobotMove command and updated SetAlternateLocation with a new mode multirobot.

...

  • Fanuc Robot always changes Robot Speed to 100 when acquiring control (ID:27440)

...

4. Known Bugs/Limitations

Internal Note:

...

...

Categorization of high priority known bugs/limitations
- Serious bugs should be listed first
- Carried-over bugs from previous versions should be listed below the latest found bugs

4.1. RapidPlan Create

...

ID

Content

Status

33873

Converting multiple auto-connects to manual connections fails if the targets to be connected for those auto-connects are the same

Fixed

31952

[TODO: Update with final state of the development] No warning is provided to user for any lost target assignments or connections when transitioning from model mode to roadmap mode

Open

34443

[Limitation] Software hangs sporadically when setting voxel size to 2mm

Open

34370

When clicking on OK in a Mate dialog, the last selected state under the Mate dialog is selected as the active state and not the state of the active preset

Open

29701

[Limitation] Validate remaining does not work when jog dialog is open

Open

Deterministic path planning is not guaranteed for clearances greater than 10cm

Open

Clearance Rule and Disable collision checking dialog allows creating a rule with same name across presets

Open

32765

Live Robot Connection makes the override speed of the teach pendant to be 100% upon connection

→ [Fixed] The override speed is not overridden by 100%

Fixed

28237

Live Connect to Kawasaki robots may fail if the robot controllers have been connected in RTR controller’s control panel previously. To use Live Connect again, the /tmp/krnx folder and its contents needs to be manually removed. The location of the /tmp/krnx folder is under /var/lib/rtr_appliance_app

Open

32731

[Limitation] Stateful targets and frame are not supported. Put in another way, any objects with any descendants such as targets and frames cannot be made stateful

Open

33990

[TODO: Update with final state of the development]Reparenting a frame that is mated to an object can cause inconsistency with mates

Open

[Remove] Unable to zoom projects that contains entities >10km from from origin (or from other entities)

Open

Reparenting a frame that is mated to an object can cause inconsistency with mates

Open

34623

Numerical calculation errors cause collision detection when a tool and link are in close proximity.

Fixed

31267

[Limitation] RPC only works properly with US-EN locale while no warning given in RPC when the wrong locale is selected. In many countries such as Germany, the decimal separator is a comma, this causes errors in RPC. Users must change the locale when working with RapidPlan.

[todo: Add to installation procedure]

Open

4.2. RapidPlan Control

ID

Content

Status

Disconnecting one robot turns off display for all robot voxels

Upgrading from a 2.3 project will delete any existing robot control logs

No warning given in CP when the wrong locale is selected

  • Only accepts US-EN

Open

19828

Interlock recording does not work with partial execution

DSM boxes, objects, and frames are tracked in the Profinet look up ID table. When items are created or removed, their Profinet IO mappings are handled as such, the handler retrieves the new id of the entity, and publishes it with Profinet. However, this does not cover cases where an external command source elicits a change in the DSM that’s unknown to a PLC.

Planning moves with DSM object attached to the robot will be rejected with an error in 2.5

...