Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

Notes

For the Realtime Controller to be able to connect to the robot controller, it must be fully powered on and in REPEAT mode.

Required Options

Kawasaki controllers must have the KRNX feature installed an enabled.

Physical Configuration

Network Configuration

The network setting should be configured properly. To do this, press the “MENU” button on the teach pendant, then select  “Aux Function” -> “System” -> “Network Setting” -> “Ethernet Port Setting”.

In the Settings menu click on Network. RTR suggests reserving 192.168.1.10 for the RTR controller, and using 192.168.1.20, 192.168.1.30, 192.168.1.40 etc for robots. The subnet mask should be set to 255.255.255.0.

Once the network configuration has been completed, RTR suggests using the Realtime Controller to ping the robot, to make sure that the two devices can communicate successfully.

Digital Input / Digital Output Settings

Realtime Controllers also communicate with Kawasaki Controllers using the DI/DO signals. We must therefore also set that up.
To do so, follow these steps :

  1. Press “R” on the Teach Pendant till you go to the home scree

  2. Press “R” again and a pop up for a code will appear

  3. Enter “611” for the code

  4. “Number of I/O Signals” Page will pop up.

  5. Fill it up like shown below

  6. Save / Restart the robot if prompted.

Realtime Controller Configuration

Kawasaki UID

If multiple Kawasaki robots are used, provide a unique UID for each robot.

The UID provided must be an integer value between 0 and 3.

  • No labels