The below describes the configuration method for RapidSense beta release.

Launch RapidSense

To launch RapidSense, first, type rapidsense at the terminal to start the core application. Second, type rtr_rapidsense_proxy to start the proxy application. Third, run the calibration service script calibration_service.py in a new terminal.

Volumes

The main configuration item related to RapidSense usage is the volume. A volume is a 3 dimensional region of interest within which dynamic obstacles are tracked and/or additional functionalities (called filters) are performed, as configured by the user. Users create, update, read, and delete volumes via the Control Panel.

Filters

Filters are operations users can add to a volume of interest to perform specific tasks. The following filters are supported:

  • Height check - return the maximum height of a surface area within the volume

  • Change detection(under developement) - identify deviations between a user provided expected template and what is sensed in the volume