Notes
For the Realtime Controller to be able to connect to the robot controller, it must be fully powered on and in REPEAT
mode.
Required Options
Kawasaki controllers must have the KRNX
feature installed an enabled.
Physical Configuration
Network Configuration
The network setting should be configured properly. To do this, press the “MENU” button on the teach pendant, then select “Aux Function” -> “System” -> “Network Setting” -> “Ethernet Port Setting”.
In the Settings menu click on Network. RTR suggests reserving 192.168.1.10 for the RTR controller, and using 192.168.1.20, 192.168.1.30, 192.168.1.40 etc for robots. The subnet mask should be set to 255.255.255.0.
Once the network configuration has been completed, RTR suggests using the Realtime Controller to ping the robot, to make sure that the two devices can communicate successfully.
Settings Configuration
Realtime Controller Configuration
Kawasaki UID
If multiple Kawasaki robots are used, provide a unique UID
for each robot.
The UID
provided must be an integer value between 0
and 3
.